What's New
OAKTON Products
Ask Our Experts
Request Literature
Distributor Program
Contact Us
Spanish Page



 

Portable meters at a glance

Product Accuracy Input connector Probe Range Resolution
Oakton Temp 16 RTD Thermometer From –328 to –148°F (–200 to –100°C): ±4°F (±2°C)
From –148 to 392°F (–99.9 to 199.9°C): ±0.4°F (±0.2°C)
From 392 to 1562°F (200 to 850°C): ±4°F (±2°C)
Standard thee-pin connector Not included –328 to 1562°F (–200 to 850.0°C)
Acorn® Temp 4 Meter ±0.2°C / ±0.4°F 6.3 mm phono jack accepts any Series 400 thermistor probe (not included) -40 to 125.0°C / -40 to 257°F 0.1°C or °F
Oakton Temp-340 Thermistor Datalogging Thermometer From 40.00 to 99.99°F (40.00 to 99.99°C): ±0.06°F (±0.03°C)
From 100.0 to 257.0°F (100.0 to 125.0°C): ±0.1°F (±0.1°C)
From 257.0 to 302.0°F (125.0 to 150.0°C): ±0.9°F (±0.5°C)
- - -40.00 to 302.0°F (-40.00 to 150.0°C)
Oakton Temp-300 Thermocouple Datalogging Thermometer Type J, K, T, E, and N:
Below -148 °F (-99.9 °C): ±0.25% of reading ±2 °F (±1 °C)
Above -148 °F (-99.9 °C): ±0.1% of reading ±0.7 °F (±0.4 °C)
- - Type J: 346 to 2192°F, Type K: 418 to 2501°F, Type T: 418 to 752°F, Type E: 418 to 1832°F, Type R: 32 to 3214°F, Type S: 32 to 3214°F
Oakton Temp 10 Thermocouple Thermometers Below -238°F (-150°C): +/-0.25% of reading +/-2°F (+/-1°C)Above -238°F (-150°C): +/-0.1% of reading +/-0.7°F +/-0.4°C) Mini-connector not included J: -346 TO 2192°F (-210 to 1200°C) K: -418 to 2501°F (-250 to 1372°C) T: -418 to 752°F (-250 to 400°C)
Oakton Temp-360 RTD Datalogging Thermometer From 330.0 to 100 °F/°C: ±0.1 °F/°C
From 99.99 to 99.99 °F/°C: ±0.06 °F/±0.03 °C
From 100.0 to 999.9°F/°C: ±0.1°F/°C
Above 1000°F/°C: ±1°F/°C
Standard thee-pin connector Not included -330 to 2210°F (-201 to 1210°C)
Oakton Temp-14 Thermistor Thermometer ± 0.4°F (± 0.2°C) : :From –40.0 °F to 257.0 °F (-40.0 to 125.0 °C)
±0.9 °F (±0.5°C) : From 257.0 to 302.0 °F (125.0 to 150.0 °C)
- One 400 or 500 series probe with 1/4" phone plug connector –40.0 °F to 302.0 °F
(-40.0 to 150.0 °C)
Acorn® Temp 5 Meter ±0.2°C / ±0.4°F 6.3 mm phono jack custom general-purpose thermistor probe (included) -40 to 125.0°C / 40 to 257°F 0.1°C or °F
Acorn® Temp 6 Meter ±0.2°C / 0.4°F (-99.9 to 199.9°C / -147.8 to 391.8°F); ±2.0°C / 4.0°F (<-99.9°C / -147.8°F and >199.9°C / 391.8°F) three-pin locking connector accepts any two-wire Pt 100 probes (alpha = 0.003850 W/W/°C) (not included) -200 to 850°C / -328 to 1562°F 0.1°C / 0.1°F (-99.9 to 199.9°C / -147.8 to 391.8°F); 1.0°C / 1.0°F (<-99.9°C / -147.8°F and >199.9°C / 391.8°F)
Acorn® Temp TC Thermocouple Thermometer ±0.25% of reading plus 1°C/2°F for temp < -99.9°C/°F
±0.25% of reading plus 0.5°C/0.9°F for temp > -99.9°C/°F
standard miniconnector accepts thermocouple probe with miniconnector (not included)
Type J: -200 to 1000°C (-328 to 1832°F)
Type K: -250 to 1372°C (-418 to 2501°F)
Type T: -250 to 400°C (-418 to 752°F)
0.1°C/°F from -299.9.9°C/°F to 299.9.9°C/°F
1°C/°F outside this range
Digi-Sense® Type K Thermometer ±0.25% of reading or ±2°F (±1°C, whichever is greater standard miniconnector accepts thermocouple probe with miniconnector (not included) -418 to 1832°F (–250 to 1372°C) 0.1° from –50.0 to 199.9°, 1° outside this range, autoranging

 
 
OAKTON Instruments: setting the standard, again and again™
OAKTON Instruments P.O. Box 5136, Vernon Hills, Il USA 60061 info@4oakton.com